Safety Investigation Report 2018:Appendix/1.6A Recent Technical Log Entries
Safety Investigation Report MH370/01/2018
Appendix 1.6A Recent Technical Log Entries SIR-APP-1.6A
APPENDIX 1.6A
RECENT TECHNICAL LOG ENTRIES
| Technical Log S/N, Date Entered and Defect | Date Entered and Rectification | |
| 1 | S/N 4918754 – 07 March 2014 Ref NTC #3 water qty indication |
07 March 2014 Potable water serviced till overflow |
| 2 | S/N 4918753 – 07 March 2014 To carry out lavatory waste |
07 March 2014 Carried out as per task card SIPCM 2-4- |
| 3 | S/N 4918753 – 07 March 2014 To carry out fwd large cargo door and |
07 March 2014 Task carried out as per AMM 12-21-21- |
| 4 | S/N 4918753 – 07 March 2014 Main entry task card T1400115-001 Ref |
07 March 2014 Said terrain database loading carried out |
| 5 | S/N 4918752 – 07 March 2014 Night Stop. Crew oxygen system |
07 March 2014 Crew oxygen system replenished to 1800 |
| 6 | S/N 4918752 – 07 March 2014 Maint : To carry out EPESC software |
07 March 2014 EPESC software downgrade carried out |
| 7 | S/N 4918751 – 06 March 2014 Maint: Record APU OPS data |
07 March 2014 APU OPS hours: 22089 APU starts: |
| 8 | S/N 4918751 – 06 March 2014 Ref NTC #3 potable water qty |
07 March 2014 Potable water serviced to overflow |
| 9 | S/N 4880500 – 06 March 2014 Both Eng require oil uplift |
06 March 2014 Both Eng require oil uplift |
| 10 | S/N 4880500 – 06 March 2014 To re inspect both eng oil caps |
06 March 2014 Both eng oil caps chkd. Found secured |
| 11 | S/N 4880499 – 06 March 2014 Maint- ref NTC #3 to service water tank |
06 March 2014 Servicing c/out and satis |
| 12 | S/N 4880498 – 05 March 2014 Autoland Cat III carried out satisfactory |
06 March 2014 Info noted. |
| 13 | S/N 4880498 – 05 March 2014 Maint entry – refer NTC #3 potable |
06 March 2014 Potable water serviced to overflow |
| 14 | S/N 4880497 – 05 March 2014 Hole found at 6 o’clock position of the |
05 March 2014 Deferred to MR2 No. K 70331 |
| 15 | S/N 4880497 – 05 March 2014 maint- ref NTC #3 potable water req. |
05 March 2014 Potable water serviced until overflow |
1 of 4
| 16 | S/N 4880496 – 05 March 2013 Maint entry – ref NTC #3 potable water |
05 March 2013 Potable water serviced to overflow satis |
| 17 | S/N 4880495 – 05 March 2014 Maint entry: w.r.t card SIPA1-4-033, to |
05 March 2014 Task carried out as per AMM task 32-41- |
| 18 | S/N 4880495 – 05 March 2014 Main entry: w.r.t cards SIPC4-4-0319 |
05 March 2014 Task carried out as per AMM task 12-13- |
| 19 | S/N 4880494 – 05 March 2014 Main entry: w.r.t. card SIPA2-6-008MR, |
05 March 2014 Task carried out as per AMM task 27-02- |
| 20 | S/N 4880494 – 05 March 2014 Maint entry – w.r.t cards SIPC4-5-001 |
05 March 2014 Task carried out as per task 12-13-03-600- |
| 21 | S/N 4880494 – 05 March 2014 Maint entry – w.r.t cards SIPL7-5- |
05 March 2014 Task carried out as per AMM task 12-21- |
| 22 | S/N 488093 – 05 March 2014 WRT SIPXE-2-6-034, 035 to carry out |
05 March 2014 Ops test carried out satis AMM 33-51-00. |
| 23 | S/N 488093 – 05 March 2014 WRT SIPX12-6-027 to carry out GPWS |
05 March 2014 Test carried out satis test passed AMM 34- |
| 24 | S/N 488093 – 05 March 2014 Maint entry – w.r.t. NTC item No. 3 |
05 March 2014 Potable water system serviced until |
| 25 | S/N 4880492 – 05 March 2014 Please check alignment for left runway |
05 March 2014 Found slight misalignment towards a/c |
| 26 | S/N 4880492 – 05 March 2014 Main entry wrt SIPX12-6-030 to carry |
05 March 2014 Ops check carried out. Test passed. Nil |
| 27 | S/N 4880492 – 05 March 2014 Main entry wrt SIPX12-4-011 to carry |
05 March 2014 Inspection carried out. Found satis. AMM |
| 28 | S/N 4880491 – 04 March 2014 Ref NTC #3 potable water ind inop |
04 March 2014 Potable water serviced to overflow |
| 29 | S/N 4880490 – 04 March 2014 During transit check found No. 4 main |
04 March 2014 No. 4 main wheel assy replaced. Torque |
| 30 | S/N 4880490 – 04 March 2014 Maint entry – w.r.t. NTC Item No. 3, water quantity indication inop |
04 March 2014 Potable water serviced until overflow |
2 of 4
| 31 | S/N 4880489 – 04 March 2014 “shadow” on rudder trim indicator from L |
04 March 2014 Rudder trim indicator replaced. Ops chk |
| 32 | S/N 4880487 – 03 March 2014 Maint entry – refer NTC #3 water qty ind |
03 March 2014 Potable water sys sucd to o/flow this |
| 33 | S/N 4880485 – 02 March 2014 For Info: APU in flt start successful |
03 March 2014 Info noted |
| 34 | S/N 4880485 – 02 March 2014 NTC #3 water qty indication is inop |
03 March 2014 Potable water sys serviced to overflow. Ref |
| 35 | S/N 4880484 – 02 March 2014 Status mssg WXR sys |
02 March 2014 MMSG: 34-44002. WXR transceiver (right) |
| 36 | S/N 4880484 – 02 March 2014 Maint entry – Refer NTC #3. Water qty |
02 March 2014 Potable water sys sucd to o/flow this |
| 37 | S/N 4880483 – 02 March 2014 Maint entry – ref: NTC 03 potable water |
02 March 2014 Potable water serviced to overflow |
| 38 | S/N 4880483 – 02 March 2014 Maint entry – No 8 Main wheel found |
02 March 2014 No 8 main wheel assy replaced as per |
| 39 | S/N 4880482 – 02 March 2014 Please carry out reinspection for all |
02 March 2014 Both engines oil caps reinspected found |
| 40 | S/N 4880482 – 02 March 2014 Please remove all landing gear pin prior |
02 March 2014 Landing gears down lock pins removed and |
| 41 | S/N 4880481 – 01 March 2014 Right hand nose taxi light lens found |
02 March 2014 Relamped ops check of right hand nose |
| 42 | S/N 4880481 – 01 March 2014 Refer NTC No. 3 potable water |
02 March 2014 Potable water serviced to overflow |
| 43 | S/N 4880480 – 28 February 2014 Nil |
01 March 2014 Noted with thanks APU data hour: 22056; |
| 44 | S/N 4880479 – 28 February 2014 Nil further |
28 February 2014 Nil noted. APU data starts 15668, hrs |
| 45 | S/N 4880478 – 28 February 2014 LLAR – Vanity light inop |
28 February 2014 TXFR to MR2 no K70329 |
| 46 | S/N 4880477 – 28 February 2014 Nil |
28 February 2014 Noted with thanks APU data hour: 22048, |
3 of 4
| 47 | S/N 4880477 – 28 February 2014 Maint entry – during W/A check found |
28 February 2014 Inspected wheel found satis. No leak |
| 48 | S/N 4880477 – 28 February 2014 Maint entry – seat 4K IFE inop |
28 February 2014 TXFR to MR2 K70328 |
| 49 | S/N 4880476 – 28 February 2014 To update FMC Nav database. |
28 February 2014. FMC Nav database updated as per |
| 50 | S/N 4880475 – 28 February 2014 To raise APU inflight start program. |
28 February 2014 Task carried out as per TSI/77/NN/09/038 |
| 51 | S/N 4880475 – 28 February 2014 Maint entry – To c/out physically chk |
28 February 2014 Task carried out. Found LH heat |
| 52 | S/N 4880475 – 28 February 2014 To carry out flt control system ACE Ops |
28 February 2014 Flt cont ACE ops test c/out as per SIPX12- |
4 of 4
Source: Safety Investigation Report - Appendix 1.6A SIR-APP-1.6A